General operating conditions
extreme lower and upper values of ambient temperature from 2740 to 3180K (from 1ºС to 45ºС);
the upper value of relative humidity of 98% at a temperature of 2980 K (250C);
height above sea level no more than 1000 m;
the temperature of the pumped liquid should be no more than 350;
pumping of aggressive liquids is prohibited;
pumping contaminated, alkaline, acidic liquids and solutions is not allowed;
water should not contain sand and other visible mechanical impurities;
mineralization of water no more than 1500 g / m3
according to the degree of protection against electric shock, the electric pump belongs to class I according to DSTU IEC60335 -2-41
according to the degree of protection against moisture, the electric pump belongs to splash-proof devices (IPX4) DSTU IEC 60335-2-41
Design
Pump part:
multistage
Engine:
asynchronous single-phase 220 V / 50Hz, oil-filled
Materials:
brass, stainless steel, food grade plastic
Equipment
cable with an electric plug, the length corresponding to the nominal depth of immersion (from 15 to 150m)
cable mounted condenser box
safety cable
Detailed description of the BZC self-priming centrifugal pump